Register a free account today to become a member! Once signed in, you'll be able to participate on this site by adding your own topics and posts, as well as connect with other members through your own private inbox!
I normally set up:
5 mail.domain.co.uk
10 mail.ispbackup.co.uk
PTR set up for domain.co.uk on you wan connection for exchange.
mail.domain.co.uk/exchange for OWA
I reckon most stuff was between 1450-1500 (including routers & laptops) and I noticed my laptop was set at the low 1400's so I did a ping fragmenation test to find the opitmal value of 1435 - anything after that and the device wouldn't reply to the ping request. MTU has never been a issue...
I'm taking a guess here but would you not have to create a form of some type?
or try this:
http://emea.windowsitpro.com/microsoftexchangeoutlook/article/articleid/23143/outlook-tips--sharing-custom-views.html
Is there anyway to relay broadcast traffic on a Windows 2003 Server acting as the a router between subnet A and Subnet B?
I've got a broadcast on port 50799udp on Subnet A but need it to broadcast on subnet B also.
192.168.1.180 is our Phone system on the engineer network - it uses a voicemail server behind the router server. The netgear you see is our switch - as our router is the zyxel of 192.168.1.254.
The lyskom is part of zyxel login page (auth kinda of thing i think).
Everything in Site A...
This a wireshark trace of the connection between server connection to Site A and B
Site B: this is the only data in the trace when trying to load the login page on the router.
Site A: this is the data in the trace with a successful connection to Site A - notice this trace shows its...
Yeah all correct that server I posted the screenshot of is our DHCP server also and my lappy is set as DHCP client.
Such a strange error - seems no way to track it down.
Maybe a faulty router in Site B or a possible ADSL2 problem.
ok heres a server on the Engineering Network that is a router. My laptop uses this to route out to the internet and connects to both site's. Yet the server itself can't load site B but can site A.
Site A:
Site B:
Stays like this forever on all laptop and PC's behind the server...
Engineering Network is 192.168.0.0 then routed through to 192.168.1.0 to the gateway of 192.168.1.254. Plug my laptop into engineering network and it works still. No proxy server involved.
Firewalls off - if you get both login screens for site A and B then it must be working, the problem is only with site B and the webpage just hangs trying to load it from site A or from engineering network.
Aye m8 - remote management over HTTP is set to allow all - so no filtering at all.
I got 2 x P-662H-D1
The odd thing I have noticed is that the ATM loop back test passes on site A but fails on site B - but I pursume thats because the Site B exchange is on the new 21cen.
ok working with my laptop and a desktop machine in the engineering network I can connect to Site B's router and the desktop can't.
The desktop can ping the router, the desktop can access the router via telnet, tracert is fine. Just won't load the http page at all.